<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>17017</ErrorNumber>
<ErrorFamily>Exposure Head</ErrorFamily>
<ErrorMessage>
HEAD: HDP parameters not initialized
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Green</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The exposure head firmware supports storing the "head dependant" parameters (HDP), however these
parameters have not been initialized.  If the head has been newly installed, the HDP parameters must be
updated manually.  If new firmware has been installed, ensure that the upgrade procedure has been
followed correctly.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
The Platesetter should operate correctly.  However, record the error message and contact Creo Service
when convenient.
</text></DescriptionText>
</OperatorAction>
<Cause>
A new head with unitialized HDP parameters
</Cause>
<Cause>
A firmware upgrade procedure has not been completed properly
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:33 2008 PST
</Updated>
<Links>
</Links>
</Error>